Authors' response
Anup Agarwal1, Nazia Nagi2, Pranab Chatterjee1, Swarup Sarkar3, Devendra Mourya4, Rima Rakeshkumar Sahay5, Rajesh Bhatia6
1 Translational Global Health Policy Research Cell, Indian Council of Medical Research, New Delhi 110 029, India 2 Department of Microbiology, Maulana Azad Medical College, New Delhi 110 002, India 3 Translational Global Health Policy Research Cell; CG Pandit Chair (Medical), Indian Council of Medical Research, New Delhi 110 029, India 4 ICMR-National Institute of Virology, Pune 411 021, Maharashtra, India 5 Maximum Containment Facility, ICMR-National Institute of Virology, Pune 411 021, Maharashtra, India 6 World Health Organization, South-East Asia Regional Office, New Delhi 110 002, India
Date of Web Publication | 20-Jun-2020 |
Correspondence Address: Anup Agarwal Translational Global Health Policy Research Cell, Indian Council of Medical Research, New Delhi 110 029 India
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/0971-5916.286224
How to cite this article: Agarwal A, Nagi N, Chatterjee P, Sarkar S, Mourya D, Sahay RR, Bhatia R. Authors' response. Indian J Med Res 2020;151:503-4 |
The authors are thankful for appreciating our work. [Figure 1] is a schematic design presented for one unit, however, in the multiple beds, air pressures will always be like that of the defined unit. The authors have presented this schematic design for the readers because if someone builds many bedded isolation units, putting the same unit in the Figure many times does not serve the purpose. As pointed out about using reduced negative pressure around -20 or -30 mm, we wish to clarify that such isolation units are needed today for COVID-19 but in future can also be used for any levels of infections caused even by risk group 4 agents. With the drawing presented in our publication for isolation wards would be useful in many such situations in the future. We know that building such facilities is not easy and these cannot be built for an individual disease.
The authors are thankful for pointing out error in [Figure 2]. The error in the Figure was that the negative pressure number 3 was wrongly depicted in the replica ward in the place of PPE room as shown in the Figure. As pointed out by you about the need of more description of [Figure 1] and [Figure 2] in the article since health professionals might not be well versed with the engineering design, we wish to inform that planning such isolation units involves many engineering issues. To cover such a vast material was beyond the scope of this manuscript. | Figure 2: (Corrected). Conceptual figure of multi-bedded isolation room for suspects.
Click here to view |
Once again we thank you for appreciating our work and pointing out error in [Figure 2].
[Figure 1]
|