ORIGINAL ARTICLE
Year : 2012  |  Volume : 136  |  Issue : 6  |  Page : 956-962

Dried blood spot HIV-1 RNA quantification: A useful tool for viral load monitoring among HIV-infected individuals in India


1 St. John's National Academy of Health Sciences, Bangalore, India
2 National AIDS Control Organization, New Delhi, India
3 Division of Global Health (IHCAR), Karolinska Institutet, Stockholm, Sweden

Correspondence Address:
Anita Shet
Department of Pediatrics, St. John's Medical College & Hospital, St. John's National Academy of Health Sciences, Sarjapur Road, Bangalore 560 034
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 23391790

Rights and PermissionsRights and Permissions

Background & objectives : Monitoring of HIV-infected individuals on antiretroviral treatment (ART) ideally requires periodic viral load measurements to ascertain adequate response to treatment. While plasma viral load monitoring is widely available in high-income settings, it is rarely used in resource-limited regions because of high cost and need for sophisticated sample transport. Dried blood spot (DBS) as source specimens for viral load measurement has shown promise as an alternative to plasma specimens and is likely to be a useful tool for Indian settings. The present study was undertaken to investigate the performance of DBS in HIV-1 RNA quantification against the standard plasma viral load assay. Methods: Between April-June 2011, 130 samples were collected from HIV-1-infected (n=125) and non-infected (n=5) individuals in two district clinics in southern India. HIV-1 RNA quantification was performed from DBS and plasma using Abbott m2000rt system after manual RNA extraction. Statistical analysis included correlation, regression and Bland-Altman analysis. Results: The sensitivity of DBS viral load was 97 per cent with viral loads >3.0 log 10 copies/ml. Measurable viral load (>3.0 log 10 copies/ml) results obtained for the 74 paired plasma-DBS samples showed positive correlation between both the assays (r=0.96). For clinically acceptable viral load threshold values of >5,000 copies/ml, Bland-Altman plots showed acceptable limits of agreement (-0.21 to +0.8 log 10 copies/ml). The mean difference was 0.29 log 10 copies/ml. The cost of DBS was $2.67 lower compared to conventional plasma viral load measurement in the setting. Interpretation & conclusions : The significant positive correlation with standard plasma-based assay and lower cost of DBS viral load monitoring suggest that DBS sampling can be a feasible and economical means of viral load monitoring in HIV-infected individual in India and in other resource-limited settings globally.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1527    
    Printed28    
    Emailed0    
    PDF Downloaded509    
    Comments [Add]    

Recommend this journal