Initial experience with real time endobronchial ultrasound guided transbronchial needle aspiration from a tertiary care hospital in north India


1 Department of Pulmonary Medicine, Postgraduate Institute of Medical Education & Research Chandigarh 160 012, India
2 Department of Cytology, Postgraduate Institute of Medical Education & Research Chandigarh 160 012, India

Date of Web Publication17-May-2013

Correspondence Address:
Ritesh Agarwal
Department of Pulmonary Medicine, Postgraduate Institute of Medical Education & Research Chandigarh 160 012
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 23703351

Rights and PermissionsRights and Permissions

How to cite this article:
Srinivasan A, Agarwal R, Gupta N, Aggarwal AN, Gupta D. Initial experience with real time endobronchial ultrasound guided transbronchial needle aspiration from a tertiary care hospital in north India. Indian J Med Res 2013;137:803-7

How to cite this URL:
Srinivasan A, Agarwal R, Gupta N, Aggarwal AN, Gupta D. Initial experience with real time endobronchial ultrasound guided transbronchial needle aspiration from a tertiary care hospital in north India. Indian J Med Res [serial online] 2013 [cited 2019 Aug 18];137:803-7. Available from: http://www.ijmr.org.in/text.asp?2013/137/4/803/112031

Sir

Transbronchial needle aspiration (TBNA) has been shown to be an effective and safe technique in the diagnosis of intrathoracic lymphadenopathy [1],[2],[3] . However, the steep learning curve, faulty techniques, unfounded concerns regarding the safety of the procedure has discouraged pulmonologists to perform this as a routine procedure [4] . A survey of pulmonary specialists in North America revealed that only 11.8 per cent of the responding pulmonary specialists routinely used TBNA while 49.4 per cent rarely used the procedure [5] . A subsequent study again demonstrated the infrequent use of TBNA with 54 per cent performing TBNA in the preceding 12 months in less than 10 instances and 18 per cent never utilizing TBNA in the prior year [6] . In a study from the United Kingdom, which reviewed the responses of 328 consultants in respiratory medicine, found that TBNA was being utilized by only 27 per cent of practitioners in the preceding 12 months due to its poor diagnostic yield [7] . The scenario has however, changed in the last decade. In a recent article with our experience of 473 TBNA procedures, we showed that the yield of TBNA improved with experience [8] . TBNA has a variable sensitivity ranging from 20-89 per cent depending on the aetiology, size and location of the lymph node, and the operator's experience [4],[9],[10],[11],[12],[13] . Despite five years of performing TBNA, the sensitivity of conventional TBNA without an on-site cytopathologist was only 40 per cent in our study. Hence, there is a need for additional modality to improve the yield of TBNA. Endobronchial ultrasound (EBUS) can improve the diagnostic yield of TBNA by enabling visualization of the lymph nodes beyond the tracheal or bronchial wall, and with the advent of the convex probe it allows real time sampling of the mediastinal and hilar lymph nodes [14] . Since the first description of EBUS-TBNA in 2003 [15] , there is no report from India describing experience with this procedure. In this study, we report our initial experience with EBUS-TBNA in patients presenting with mediastinal lymphadenopathy of unknown aetiology in a tertiary care hospital in north India.

A prospective review of all consecutive EBUS-TBNA procedures performed at the department of Pulmonary Medicine, Postgraduate Institute of Medical Education & Research, Chandigarh, over three months period (July 15 to October 15, 2011) was done. The study was approved by the institutional Ethics Committee and an informed consent was obtained from all patients. All patients undergoing diagnostic bronchoscopy for intrathoracic lymphadenopathy identified on computed tomography (CT) scan of the chest, irrespective of the aetiology, were offered the option of EBUS-TBNA. Patients not willing for EBUS-TBNA due to the cost associated with the dedicated EBUS-TBNA needle underwent conventional TBNA. A detailed history, physical examination, radiological findings and provisional clinical diagnosis were recorded. Lymph nodes were considered enlarged and amenable for TBNA when the short axis nodal diameter on CT chest was >1 cm, and were classified using the Association for the Study of Lung Cancer (IASLC) classification [16] . All patients received nebulized lignocaine (4% solution) immediately before the procedure, coupled with injection of 0.6 mg atropine and 25 mg promethazine intramuscularly. Intravenous midazolam was used as the agent for sedation and pentazocine for analgesia, and the total dose required was noted in each patient. Topical 10 per cent lignocaine spray was applied in the oropharynx augmented with 'spray-as-you-go' 2 per cent lignocaine over the vocal cords and the airways. Bronchoscopy was done on an outpatient basis using the EBUS scope (BF-UC 180F; Olympus Medical Systems, Singapore) with a compatible endoscopic ultrasound unit (EU-ME1; Olympus Medical Systems, Singapore). The procedure was done in the supine position through the oral route.The dimension of the lymph nodes were documented by measuring the short axis diameter of the nodes on EBUS once the best view of the node was identified. All TBNA specimens were obtained using a dedicated, disposable, 21-gauge, Vizishot needle (NA-201SX-4021 Olympus Medical Systems, Singapore) using the jabbing method under real-time ultrasound control. The same needle was used for all stations as the aim of EBUS-TBNA in this study was only diagnostic. We used 21G instead of 22G due to proposed better preservation of histological structure of the samples with the larger needle [17] . Continuous suction was applied with a dedicated 20 ml syringe while the catheter was moved back and forth for up to a maximum of 20 times. A maximum of three aspirates were obtained from each location; only two aspirates were obtained if a core biopsy specimen was identified [18] . In case of multiple lymph node enlargements, the most enlarged lymph nodes were accessed. On-site cytological assessment for adequacy of the sample was not available. Secretions and cough during the procedure was rated by the operator using a visual analog scale (VAS) from 0-100 millimeters. Bronchoalveolar lavage (BAL), transbronchial biopsy (TBB) and endobronchial biopsy (EBB) were also done as clinically indicated using the conventional flexible bronchoscope. An experienced cytopathologist examined all the smears for adequacy of samples and definite diagnosis. Adequate lymph node samples were defined by preponderance of benign lymphocytes, and represented a successful procedure. Malignancy was diagnosed based on the representative samples containing malignant cells. In the presence of compatible clinicoradiological features, compact epithelioid cell granuloma without necrosis and negative acid-fast bacilli (AFB) smears was considered diagnostic of sarcoidosis. Smears were considered diagnostic of tuberculosis (TB) in the presence of extensive necrotizing granulomas and/or demonstration of AFB. In patients with suspected TB, the aspirates were also sent for mycobacterial cultures by the mycobacterial growth indicator tube technique. All patients with negative EBUS are given an option to undergo CT-guided fine needle aspiration cytology, and were followed up for six months to determine the actual diagnosis, however, no patient underwent mediastinoscopy.

A total of 483 bronchoscopies were done during the study period, and 46 patients (9.5%) were considered eligible for TBNA. Of these, 39 patients (8.1%) underwent EBUS-TBNA while the remaining underwent conventional TBNA. There were 23 men and 16 women with a median age of 43 yr. The most common clinical diagnosis was sarcoidosis followed by tuberculosis and lung cancer [Table 1]. A total of 71 nodes were sampled in 39 patients. The median number of lymph node groups enlarged on CT was two, and a median of two lymph node sites were accessed in every patient [Table 2]. Adequate lymph node sampling (i.e. presence of lymphocytes) was obtained in 37 patients while a diagnostic sample was obtained in 27(69.2%) patients [Table 2]. The diagnostic yield increased to 73 per cent (27 of 37) after excluding cases without adequate lymph node sampling. Of the 21 patients suspected to have sarcoidosis, three were diagnosed as tuberculosis based on EBUS. Of the 18 patients, in two patients with suspected sarcoidosis EBUS-TBNA was representative but no granulomas could be demonstrated in EBUS, TBB and EBB. Both the patients were followed up without treatment for 6 months. There was no enlargement of lymph nodes and no evidence of sarcoid activity at any other site, and thus were deemed to have idiopathic mediastinal adenopathy. Thus, EBUS cytology was able to establish diagnosis of sarcoidosis in 12 of 16 patients. TBB and EBB enabled diagnosis in four additional patients where EBUS was non-contributory. EBUS was able to establish a diagnosis of TB in nine of 14 patients, of whom two were positive for AFB and four were culture positive on EBUS aspirate. Of the remaining five patients, two were diagnosed on CT guided FNAC while the lymph nodes of three patients resolved after an empiric trial of anti-tuberculosis therapy. The sensitivity of EBUS-TBNA was 85.7 per cent in patients with a clinical diagnosis of lung cancer [Table 3]. One patient negative on EBUS was diagnosed to have squamous cell carcinoma on CT-guided FNAC. Most patients tolerated the procedure with median (IQR) VAS for secretions and cough being 19 and 24 mm, respectively. The median dose of midazolam was 8 mg per procedure, and the median duration of procedure was 40 min [Table 2]. Minor complications were encountered in four patients (10.3%) which included post procedure chills in two patients, prolonged sedation in one and minor bleed with hypoxemia requiring high flow oxygen supplementation through Venturi mask in one patient. However, none required admission for the complications.
Table 1. Baseline characteristics of 39 patients with mediastinal lymphadenopathy who underwent real-time EBUS-TBNA

Click here to view
Table 2. Procedural details of patients undergoing EBUSTBNA

Click here to view
Table 3. Sensitivity and specificity of EBUS-TBNA in mediastinal lymphadenopathy

Click here to view


Diagnosis of mediastinal lymphadenopathy remains a challenge for respiratory physicians. We were able to achieve representative samples in 94.9 per cent of patients, and confirmation of diagnosis was established in 69.2 per cent. Other studies have reported higher diagnostic yield, ranging from 93.5-100 per cent [19],[20],[21],[22],[23] . These studies have evaluated suspected mediastinal metastasis of bronchogenic carcinoma or diagnosis of suspected malignancy. In our study, the diagnostic yield of EBUS in patients with clinical suspicion of malignancy was 85.7 per cent and was in agreement with a recent systematic review evaluating the role of EBUS in patients with suspected malignancy [24] . Our results were comparable to studies evaluating learning curve and early experience in centers starting an EBUS-TBNA programme evaluating enlarged lymph nodes irrespective of aetiology, where the diagnostic yield has ranged from 63-67 per cent [25],[26],[27] . However, the target should be a sensitivity of 88-90 per cent for malignancy [28] . The sensitivity of EBUS in sarcoidosis was 75 per cent and was better than the yield of conventional TBNA (38.1%) reported from our center [8] . The sensitivity of EBUS-TBNA in sarcoidosis has ranged from 50-97 per cent [27],[29],[30],[31],[32] , and the lower diagnostic yield in our study is likely due to the small sample size, less number of passes per node and the learning curve associated with the procedure. In patients with suspected tuberculosis, the sensitivity of EBUS was 64.3 per cent even after smear and culture. Additionally, EBUS diagnosed TB in three patients who were initially thought to be sarcoidosis on clinical grounds. The yield of EBUS-TBNA in TB has been reported to be 94 per cent in a recent study [33] . The lower yield apart from the learning curve and non-availability of rapid on-site cytological evaluation, is possibly due to the fact that several of our patients had been started on anti tuberculous therapy on the basis of clinical suspicion. Another reason could be lack of performance of systematic examination of nodes from proximal to distal stations regardless of nodal size on CT. As the aim of EBUS-TBNA in this study was only diagnostic, the largest lymph nodes identified on CT were sampled. The patients were followed only for 6 months after a negative EBUS-TBNA leading to a risk of missing other pathologies which appeared after 6 months. Also not being able to validate negative EBUS-TBNA with mediastinoscopy (which was not available on- site) was another limitation.

In conclusion, EBUS-TBNA may be a promising tool for interventional pulmonologist enabling minimally invasive access to mediastinal nodes under real-time guidance. Our preliminary experience suggested that the sensitivity of EBUS-TBNA for diagnosing of intrathoracic lymphadenopathy was better than conventional TBNA.


   Acknowledgment Top


This work was supported by a FIST grant from the Department of Science & Technology, New Delhi, India.

 
   References Top

1.Holty JE, Kuschner WG, Gould MK. Accuracy of transbronchial needle aspiration for mediastinal staging of non-small cell lung cancer: a meta-analysis. Thorax 2005; 60 : 949-55.  Back to cited text no. 1
    
2.Detterbeck FC, Jantz MA, Wallace M, Vansteenkiste J, Silvestri GA. Invasive mediastinal staging of lung cancer: ACCP evidence-based clinical practice guidelines (2nd edition). Chest 2007; 132 (3 Suppl): 202S-20S.  Back to cited text no. 2
    
3.Medford AR, Agrawal S, Free CM, Bennett JA. A prospective study of conventional transbronchial needle aspiration: performance and cost utility. Respiration 2010; 79 : 482-9.  Back to cited text no. 3
    
4.Dasgupta A, Mehta AC. Transbronchial needle aspiration. An underused diagnostic technique. Clin Chest Med 1999; 20 : 39-51.  Back to cited text no. 4
    
5.Prakash UB, Offord KP, Stubbs SE. Bronchoscopy in North America: the ACCP survey. Chest 1991; 100 : 1668-75.  Back to cited text no. 5
    
6.Colt HG, Prakash UBS, Offord KP. Bronchoscopy in North America: Survey by the American Association for Bronchology, 1999. J Bronchology Interv Pulmonol 2000;7 : 8-25.  Back to cited text no. 6
    
7.Smyth CM, Stead RJ. Survey of flexible fibreoptic bronchoscopy in the United Kingdom. Eur Respir J 2002; 19 : 458-63.  Back to cited text no. 7
    
8.Khan A, Agarwal R, Aggarwal AN, Gupta N, Bal A, Singh N, et al. Blind transbronchial needle aspiration without an on-site cytopathologist: experience of 473 procedures. Natl Med J India 2011; 24 : 136-9.  Back to cited text no. 8
    
9.Harrow EM, Oldenburg FA, Smith AM. Transbronchial needle aspiration in clinical practice. Thorax 1985; 40 : 756-9.  Back to cited text no. 9
    
10.Schenk DA, Bower JH, Bryan CL, Currie RB, Spence TH, Duncan CA, et al. Transbronchial needle aspiration staging of bronchogenic carcinoma. Am Rev Respir Dis 1986; 134 : 146-8.  Back to cited text no. 10
    
11.Harrow EM, Oldenburg FA, Jr., Lingenfelter MS, Smith AM, Jr. Transbronchial needle aspiration in clinical practice. A five-year experience. Chest 1989; 96 : 1268-72.  Back to cited text no. 11
    
12.Gay PC, Brutinel WM. Transbronchial needle aspiration in the practice of bronchoscopy. Mayo Clin Proc 1989; 64 : 158-62.  Back to cited text no. 12
    
13.Haponik EF, Shure D. Underutilization of transbronchial needle aspiration: experiences of current pulmonary fellows. Chest 1997; 112 : 251-3.  Back to cited text no. 13
    
14.Burgers JA, Herth F, Becker HD. Endobronchial ultrasound. Lung Cancer 2001; 34 (Suppl 2): S109-13.  Back to cited text no. 14
    
15.Krasnik M, Vilmann P, Larsen SS, Jacobsen GK. Preliminary experience with a new method of endoscopic transbronchial real time ultrasound guided biopsy for diagnosis of mediastinal and hilar lesions. Thorax 2003; 58 : 1083-6.  Back to cited text no. 15
    
16.Rusch VW, Asamura H, Watanabe H, Giroux DJ, Rami-Porta R, Goldstraw P. The IASLC lung cancer staging project: a proposal for a new international lymph node map in the forthcoming seventh edition of the TNM classification for lung cancer. J Thorac Oncol 2009; 4 : 568-77.  Back to cited text no. 16
    
17.Nakajima T, Yasufuku K, Takahashi R, Shingyoji M, Hirata T, Itami M, et al. Comparison of 21-gauge and 22-gauge aspiration needle during endobronchial ultrasound-guided transbronchial needle aspiration. Respirology 2011; 16 : 90-4.  Back to cited text no. 17
    
18.Lee HS, Lee GK, Kim MS, Lee JM, Kim HY, Nam BH, et al. Real-time endobronchial ultrasound-guided transbronchial needle aspiration in mediastinal staging of non-small cell lung cancer: how many aspirations per target lymph node station? Chest 2008; 134 : 368-74.  Back to cited text no. 18
    
19.Herth FJ, Eberhardt R, Vilmann P, Krasnik M, Ernst A. Real-time endobronchial ultrasound guided transbronchial needle aspiration for sampling mediastinal lymph nodes. Thorax 2006; 61 : 795-8.  Back to cited text no. 19
    
20.Bauwens O, Dusart M, Pierard P, Faber J, Prigogine T, Duysinx B, et al. Endobronchial ultrasound and value of PET for prediction of pathological results of mediastinal hot spots in lung cancer patients. Lung Cancer 2008; 61 : 356-61.  Back to cited text no. 20
    
21.Yasufuku K, Chiyo M, Koh E, Moriya Y, Iyoda A, Sekine Y, et al. Endobronchial ultrasound guided transbronchial needle aspiration for staging of lung cancer. Lung Cancer 2005; 50 : 347-54.  Back to cited text no. 21
    
22.Yasufuku K, Nakajima T, Motoori K, Sekine Y, Shibuya K, Hiroshima K, et al. Comparison of endobronchial ultrasound, positron emission tomography, and CT for lymph node staging of lung cancer. Chest 2006; 130 : 710-8.  Back to cited text no. 22
    
23.Vincent BD, El-Bayoumi E, Hoffman B, Doelken P, DeRosimo J, Reed C, et al. Real-time endobronchial ultrasound-guided transbronchial lymph node aspiration. Ann Thorac Surg 2008; 85 : 224-30.  Back to cited text no. 23
    
24.Varela-Lema L, Fernandez-Villar A, Ruano-Ravina A. Effectiveness and safety of endobronchial ultrasound-transbronchial needle aspiration: a systematic review. Eur Respir J 2009; 33 : 1156-64.  Back to cited text no. 24
    
25.Tian Q, Chen LA, Wang HS, Zhu BH, Tian L, Yang Z, et al. Endobronchial ultrasound-guided transbronchial needle aspiration of undiagnosed mediastinal lymphadenopathy. Chin Med J (Engl) 2010; 123 : 2211-4.  Back to cited text no. 25
    
26.Arslan Z, Ilgazli A, Bakir M, Yildiz K, Topcu S. Conventional vs. endobronchial ultrasound-guided transbronchial needle aspiration in the diagnosis of mediastinal lymphadenopathies. Tuberk Toraks 2011; 59 : 153-7.  Back to cited text no. 26
    
27.Jernlas B, Nyberger H, Ek L, Ohman R, Jonsson P, Nozohoor S. Diagnostic yield and efficacy of endobronchial ultrasound-guided transbronchial needle aspiration in mediastinal lymphadenopathy. Clin Respir J 2012; 6 : 88-95.  Back to cited text no. 27
    
28.Medford AR, Agrawal S, Free CM, Bennett JA. A performance and theoretical cost analysis of endobronchial ultrasound-guided transbronchial needle aspiration in a UK tertiary respiratory centre. QJM 2009; 102 : 859-64.  Back to cited text no. 28
    
29.Wong M, Yasufuku K, Nakajima T, Herth FJ, Sekine Y, Shibuya K, et al. Endobronchial ultrasound: new insight for the diagnosis of sarcoidosis. Eur Respir J 2007; 29 : 1182-6.  Back to cited text no. 29
    
30.Oki M, Saka H, Kitagawa C, Tanaka S, Shimokata T, Kawata Y, et al. Real-time endobronchial ultrasound-guided transbronchial needle aspiration is useful for diagnosing sarcoidosis. Respirology 2007; 12 : 863-8.  Back to cited text no. 30
    
31.Garwood S, Judson MA, Silvestri G, Hoda R, Fraig M, Doelken P. Endobronchial ultrasound for the diagnosis of pulmonary sarcoidosis. Chest 2007; 132 : 1298-304.  Back to cited text no. 31
    
32.Cetinkaya E, Gunluoglu G, Ozgul A, Gunluoglu MZ, Ozgul G, Seyhan EC, et al. Value of real-time endobronchial ultrasound-guided transbronchial needle aspiration. Ann Thorac Med 2011; 6 : 77-81.  Back to cited text no. 32
    
33.Navani N, Molyneaux PL, Breen RA, Connell DW, Jepson A, Nankivell M, et al. Utility of endobronchial ultrasound-guided transbronchial needle aspiration in patients with tuberculous intrathoracic lymphadenopathy: a multicentre study. Thorax 2011; 66 : 889-93.  Back to cited text no. 33
    



 
 
    Tables

  [Table 1], [Table 2], [Table 3]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
   Acknowledgment
    References
    Article Tables

 Article Access Statistics
    Viewed565    
    Printed13    
    Emailed0    
    PDF Downloaded212    
    Comments [Add]    

Recommend this journal