Indan Journal of Medical Research Indan Journal of Medical Research Indan Journal of Medical Research Indan Journal of Medical Research
  Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login  
  Home Print this page Email this page Small font sizeDefault font sizeIncrease font size Users Online: 632       

   Table of Contents      
CORRESPONDENCE
Year : 2012  |  Volume : 136  |  Issue : 6  |  Page : 1060-1061

Authors' response


Department of TB & Respiratory Diseases, Mahatma Gandhi Institute of Medical Sciences, Sevagram 442 102, India

Date of Web Publication4-Feb-2013

Correspondence Address:
Sajal De
Department of TB & Respiratory Diseases, Mahatma Gandhi Institute of Medical Sciences, Sevagram 442 102
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions

How to cite this article:
De S. Authors' response. Indian J Med Res 2012;136:1060-1

How to cite this URL:
De S. Authors' response. Indian J Med Res [serial online] 2012 [cited 2019 Jun 20];136:1060-1. Available from: http://www.ijmr.org.in/text.asp?2012/136/6/1060/106923

Sir,

I thank Drs Dhara and Acquilla for their interest in my article [1] and appreciate their suggestion to analyze the exposure-response relationship using the distance of individual residence at the time of disaster. The surrogate markers used in earlier studies to determine the severity of MIC exposure are: death of family members or neighbours, immediate symptoms and severity of symptoms, hospitalization, perceptions of the presence of MIC and locality of residence at the time of disaster [2] . Except for the distance of residence from the Union Carbide Plant, the collection of other parameters from illiterate (61% population in severely affected area 41% in moderate to mildly affected area were illiterate) [2] after two decade are subjected to high recall bias. The effect of distance of residence was further influenced by additional variables, e.g. duration of exposure, protective measures used by them at that time (i.e. cover of face, splashing of water on face, etc.), and their activity after the disaster (i.e. ran away from their houses, stayed inside their house). Therefore, the distance of individual residence at the time of disaster alone may be inadequate to assess the severity to MIC exposure. The approximate distance of residence of our study population was calculated using their registration numbers (registration numbers were assigned as per satellite heath centers nearer to their original residence) and no differences in prevalence of different lung function abnormalities was observed.

The IMCB survey [3] reported high respiratory morbidity among exposed survivors and documented its relationship with the distance of residence from the Plant. The FEF 25-75% was significantly reduced (84% of predicted) among those who were residing nearer to the plant. However, no such association was observed for the other important indices of lung function i.e. FEV 1 , FVC and FEV 1 /FVC. The FEF 25-75% , is a variable spirometric parameter to assess small airway function and it depends upon the subjects' expiratory effort during spirometry [4] . Therefore, the FEF 25-75% values were not utilized in this study [1] .

Unlike previous studies, the result demonstrated the high prevalence of obstructive lung function abnormalities among gas victims [1] . The observation was based on retrospective analysis of spirometry data and hence the direct exposure-response relationship could not be evaluated. It was postulated that cumulative effect of other known confounding factors for developing obstructive lung function i.e. smoking, low economic conditions might have influenced the observations. Even after excluding the current and ex smoker from both the groups, the relative risks in our study remained similar. The community based study using these results will be required to determine the true association of MIC and lung function abnormalities.

 
   References Top

1.De S. Retrospective analysis of lung function abnormalities of Bhopal Gas Tragedy affected population. Indian J Med Res 2012; 135 : 193-200.  Back to cited text no. 1
    
2.Technical Report on Population Based Long Term Epidemiological Studies (1985-1994): Indian Council of Medical Research, New Delhi. Available from: http://www.nireh.org/TR-Epid.pdf, accessed on July 30, 2012.  Back to cited text no. 2
    
3.Cullinan P, Acquilla S , Dhara VR. Bhopal respiratory morbidity 10 years after the Union Carbide gas leak at Bhopal: a cross sectional survey. The International Medical Commission on Bhopal. BMJ 1997; 314 : 338-42.  Back to cited text no. 3
    
4.Miller MR, Hankinson J, Brusasco V, Burgos F, Casaburi R, Coates A, et al; ATS/ERS Task Force. Standardisation of spirometry. Eur Respir J 2005; 26 : 319-38.  Back to cited text no. 4
    




 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    References

 Article Access Statistics
    Viewed309    
    Printed11    
    Emailed0    
    PDF Downloaded163    
    Comments [Add]    

Recommend this journal